It wouldn’t be bad to fix the column yourself and save on calling a repairman, wouldn’t it? But how to diagnose the cause of the breakdown and what to do next? We will talk about all this in this publication - we will consider the popular malfunctions of the Electrolux brand gas water heater, the procedure for determining the cause and methods for restoring performance. For clarity, we will provide the article with photos and thematic videos.

E1 - Problem with ignition

After opening the water tap, the column starts up and ignition clicks are heard. After unsuccessful attempts to ignite the gas, the dispenser “goes” into emergency mode.

Reason #1. Weak battery power. Replace the batteries (batteries). Remember, expensive batteries are no better than cheap ones.

Reason #2. The ignition electrode is faulty. The spark hits the housing and does not reach the burner. When turning on the speaker, look under the case. The breakdown site is illuminated by a spark.

Note! Troubleshooting, replacement of parts and repair of the gas water heater is carried out by a qualified technician from the service center. Self-repair and installation of supply communications provoke gas leaks, use the services of trained craftsmen.

Reason #3. The gas opening valve is broken. The valve is replaced by a specialist from the service center.

Diagnostics

We diagnose the geyser over the phone, so the cost of this service for you is

0 Rubles

Call

We will charge 500 rubles for the call if the repair is refused, but this service is worth it to you

0 Rubles

Repair

The cost of the work performed excluding the cost of the required spare parts varies.

From 900 rubles

Guarantee

Before leaving, our employees will issue a guarantee from our company for the work done for a period of time.

Up to 12 months

How to avoid common breakdowns?

Those who follow the simplest safety rules when operating gas-using equipment will not have to worry about the technical condition of their dispenser.


The geyser is installed in a room that can be regularly ventilated. This requirement is mandatory, otherwise the gas service will not issue permission to connect the water heater.

The simplest tips will help prevent typical breakdowns:

  • The gas water heater must be installed out of the reach of children. Otherwise, the child will damage the equipment or be injured.
  • Particular attention should be paid to the door in the room where the equipment is installed. There should be a gap (2 cm) under the door. This will be enough for ventilation.
  • Directly during operation of the column, it is advisable to open the window, if such an opportunity is provided in the room where it is installed.
  • If your water heater is in a room that is not heated (for example, in a summer cottage), then in winter all remaining water should be removed from the water heater.
  • Some parts of the geyser structure become very hot, so touching them is dangerous - you can get burned.
  • Under no circumstances should you tie clotheslines to gas pipes and dry clothes on them. Access to gas pipes should be extremely simple.

If you use the column for a long time, then you need to regularly check the chimney draft.


In order to check the draft at home, just hold a match to the chimney and determine the presence of air flow. This will be obvious from the movement of the flame

Adjusting the Electrolux geyser

First, you need to come to terms with the fact that you need to entrust the installation of the column to a specialist. If you install this equipment yourself, the service center may refuse warranty service, as many manufacturers warn about.

There are requirements for rooms in which a gas water heater can be installed. The area of ​​such a room should not be less than 12 square meters. m. Ceiling height - at least 2.2 m. There must be vents or opening windows. If you do not have such a room, then installing a gas water heater is not allowed.

However, many problems arise precisely because of insufficiently competent installation and adjustment of the gas water heater, so you must carefully monitor the work of the installation technician. If it seems to you that he is ignoring the rules described in SNiP 2.04.08-87, then you should call another specialist in the installation of geysers.

The very first launch is possible only in the presence of an inspector from the gas service. It is prohibited to connect the dispenser yourself, as stated in paragraph 88 (1) of Section VIII of the Government of the Russian Federation Resolution N 410 dated 05/14/2013 (date of update 01/01/2019) “On measures to ensure safety when using... gas equipment.” This must be carried out by a qualified specialist.

Correct speaker setup

Breakdowns often appear after improper equipment setup. In order to adjust the operating mode of the equipment, you need to use the display, which is equipped with almost all Electrolux speakers. This display is connected to a sensor that monitors the water temperature.


All modern Electrolux geysers are equipped with a display that displays all important information regarding the operation of the water heater, including water temperature and battery charge level, if the model requires their use

In order to change the power, you need to change the intensity of the fire. A display with indicators will help you with this. In some Electrolux geysers (with flame modulation), you need to set the desired water heating temperature. This is how the operation of the equipment is adjusted. After this, the burner power will change.

Remember that you can only adjust the temperature in the specified way. If you mix cold water with hot water, you will only aggravate the situation and ruin the gas water heater.

Gas equipment cleaning

Many breakdowns can be avoided by regular maintenance and cleaning of individual elements of the column structure that are most susceptible to contamination. In geysers from this manufacturer, such parts include the burner and heat exchanger.

Burner jets often become clogged due to soot, and scale often appears inside the heat exchanger. Carbon deposits can be seen on the outside of the heat exchanger.


Cleaning the column heat exchanger with an acid-containing solution can be done on your own. It is best to clean the gas water heater in the fresh air.

You can clean the device yourself only if the warranty has already expired. Otherwise, you should call the service center, because during the warranty period, specialists will remove all dirt for free.

If the warranty has already expired, then you need to remove the column casing, remove the heat exchanger and remove the burner. The tubes inside can be washed using conventional chemicals, and the radiator fins outside can be washed with a regular solution (soap). It is recommended to clean the burner using a metal awl.

Gas water heater security system

Each speaker produced by Electrolux is equipped with a multi-level security system. It is designed to prevent gas and water leaks. When the pressure increases, the protection system should work and turn off the column.

Of all the malfunctions, the greatest threat is caused by breakdowns that lead to gas leaks, so it is recommended to give preference to models with an automatic shutdown function. We also advise you to familiarize yourself with the reasons for the explosion of a gas water heater.

E2 - coolant overheating

Water temperature is above 85 °C. The geyser overheats and turns off.

Reason #1. The filter element is clogged. Clean the filter at the water inlet and outlet of the column, at the mixer tap.

Reason #2. Soot on the heat exchanger heater. Soot is removed as part of maintenance which includes: cleaning the burner, washing the heat exchanger.

Reason #3. Scale on the walls of the heat exchanger tube. The heat exchanger should be washed with a weak solution of hydrochloric acid or acetic acid solution.

Geyser Ariston: review of models and costs

Equipment from the Italian manufacturer Ariston has long gained consumer recognition due to the high-quality assembly of devices and their long service life. It also makes sense to note the affordability of the devices, which is ensured by their assembly in China. The productive gas water heater Ariston is developed using a special technology, due to which it is fully adapted to Russian conditions, for example, operation at low levels of water pressure, power surges in the network, etc.

E4 - no traction

The speaker runs for 2-3 minutes and turns off. Restarting is possible after 5 minutes, after cooling.

Reason #1. The ventilation duct is clogged. There is a large accumulation of carbon monoxide near the column; the ventilation duct will need to be cleaned. Using the speaker is prohibited!

Reason #2. The heat exchanger is heavily sooted with soot. When turned on, black flakes fall. Invite a technician for maintenance; the device needs cleaning.

Technical characteristics of the device

Series With 125 V C 150S With 275 S/SE/SEI From 275 V With 350 S/SEI
Net power kW (kcal/min) 8.7 (125) 10.4 (150) 19.2 (275) 19.2 (275) 24.4 (350)
Power consumption kW (kcal/min) 10.4(150) 12.4 (178) 22.7 (326) 22.7 (326) 29(416)
efficiency % 84 84 84 84 84
Nominal gas pressure
Natural gas mbar (mm.w.st.) 13 (130) 13 (130) 13 (130) 13 (130) 13(130)
Liquefied gas (G30) mbar (mm.w.st.) 30 (300) 30 (300) 30 (300) 30 (300) 30 (300)
Nominal gas consumption
Natural gas m3/h 1.0 1.3 2.3 2.3 3.0
Liquefied gas (G30) kg/h 0.8 0.9 1.7 1.7 2.2
Water consumption
- minimal l/min 2.7 2.7 2.7 2.7 2.7
— maximum l/min 5 6 11 11 14
Water temperature difference
- at minimum consumption °C 45 45 45 68 45
- at maximum flow °C 25 25 25 25 25
Water pressure
— minimum* Atm (kPa) 0.1 (10) 0.1 (10) 0.1 (10) 0.1 (10) 0.1 (10)
— minimum** Atm (kPa) 0.1 (10) 0.5 (50) 0.5 (50) 0.1 (10) 0.5 (50)
— maximum Atm (mPa) 10(1.0) 10 (1.0) 10 (1.0) 10 (1.0) 10 (1.0)
Connection fittings
— inflow (cold water) inch ¾ 3/4 3/4 3/4 3/4
— selection (hot water) inch ½ 1/2 1/2 1/2 1/2
— gas supply inch ½ 1/2 1/2 1/2 1/2
Dimensions
- with packaging mm 460x290x266 595x290x266 635x361x270 635x361x270 720x430x285
— without packaging mm 415x250x220 550x250x220 575x310x220 575x310x220 640x380x225
gas outlet pipe mm absent 86 110 110 130
Weight
- with packaging kg 8.5 9.3 12.1 12.1 15.3
— without packaging kg 7.2 8 10.8 10.8 13.6

The device complies with GOST 20219-93. The average service life of the device is 12 years.

* - water flow regulator is closed, ** - water flow regulator is completely open.

Ignition type : models B, S - piezo; models SE, SEI - electric; The average service life of the device is 12 years.

Causes

It is worth considering that breakdowns can be of a very different nature. For example:

  • the flame does not ignite (clicks, there is a spark, but it does not work or there is no reaction to switching on at all);
  • goes out immediately or after a short time (both with automatic and manual ignition);
  • the fire goes out when you try to turn on the water, increase the pressure or weaken it;
  • the flame ignites, the water comes out lukewarm, and then the column goes out;
  • the speaker pops, crackles, mini-explosions appear when turned on;
  • piezo ignition does not work;
  • the piece works constantly, but when ignited the flame goes out;
  • the dispenser does not light up and there is a smell of gas;
  • When the tap is opened, the GSV rod does not move.

Column malfunctions can be divided into breakdowns caused by external factors and those of a purely internal nature. The former are not related to parts inside the unit itself and depend on additional parts or external influences (for example, adding temperature).

External factors

External breakdowns are as follows.

  • The most common situation is the lack of draft in the chimney of the column. If it is not cleaned, it will become clogged with dust and dirt, and combustion products will not find an outlet and will extinguish the burner. Then, when the security system is activated, the gas supply will be cut off.
  • A foreign object could accidentally end up in the chimney.
  • The unit could simply have run out of battery or batteries. This type of malfunction only exists if there is an ignition, which operates automatically using batteries.
  • If the device does not work after the first installation or due to repair work on the plumbing system, then there is a high probability that the hot water supply line was simply connected in the wrong place.
  • Reduced water pressure. It is necessary to evaluate the water pressure (it will be weakened, the water will flow in a thin stream). The ignition will stop working with low pressure, so the reason is no longer in the column, but in the water pipes. Although, it is likely that the filter itself, installed in front of the column, is clogged with something.
  • A faulty faucet that adds too much cold water, causing the water in the tap itself to heat up too much and extinguish it.
  • Electronics. Modern speakers contain a large number of control modules and sensors that control the operation of the entire unit. Their failures can lead to the gas stopping igniting.

Internal breakdowns

Internal factors are like this.

  • Incorrectly configured water heater. Due to the change of seasons, the water temperature also changes, so the column needs to be adjusted, which is often forgotten to do.
  • The membrane on the water unit has failed. If the membrane is many years old, it could have lost its elasticity, cracked, deformed, or become covered with lime deposits.
  • Filters or heat exchanger clogged with soot and scale.
  • The pilot or main burner is clogged with dirt.
  • Problems with the gas outlet sensor.
  • Pops or small explosions when trying to turn on the equipment can occur due to insufficient draft in the ventilation or blockages of various parts of the water heater.

Work principles

A thermocouple is two welded conductors. One is made of alumel and chromel. The thermocouple has one main function - supplying power to the solenoid valve.

Such a part rarely fails. At the exit from the housing there is a bottleneck equipped with a central conductor. The latter is equipped with high-quality insulation, but even it sometimes gets worn out, causing the speakers to go out.

Another problem is contact failure at the thermocouple welding points. In this case, it is impossible to restore the original characteristics. After all, the current generator passes through the same place. It is recommended to purchase a replacement for the old part.

A solenoid valve is also known as a copper wire coil. Inside this structure there are metal cylinders called a solenoid. There is a mechanical connection between this part and the shut-off valve for gas to enter the burner.

When the thermocouple heats up, a current is generated. It creates a magnetic field when passing through the coil. It is due to this that the solenoid is pulled inward. The solenoid also has a mechanical connection with the valve. Gas flows to the igniter when the valve is moved.

The thermocouple cools down if the gas does not ignite. Because of this, current production stops. The gas supply stops altogether as the solenoid itself returns to its original position.

This is how you can ensure safe operation of devices under various conditions. This is also due to the fact that problems can arise due to a simple blow of wind if the systems are not equipped with protective mechanisms.

A bimetallic plate is how a thermal fuse can be described. The plate begins to sag when the temperature where the part is installed reaches 90 degrees.

The solenoid power supply circuit is then broken. The thermal fuse is connected to the general circuit using special terminals.

It often breaks due to the fact that the design is complex and has a lot of features.

Reasons for extinction after ignition

If the gas water heater goes out or functions unstably, it is necessary to establish the cause of the problem. For these purposes, you need to find out what causes malfunctions in the functioning of the device. Often the device does not turn on due to:

  • turning on an indicator that detects a gas leak;
  • difficulties with the chimney;
  • valve failure;
  • wick clogging;
  • main burner attenuation;
  • too much ventilation;
  • thermocouple opening;
  • breakdown of the automatic system.

Important! If the column smokes, turns off, or does not light up at all, you can try to solve the problem yourself. However, it is best to call a specialist in such a situation.

Flame ionization sensor failure

When the device turns on and starts to go out, the ionization indicator is 70% at fault. This component is regularly in contact with fire. The ions produced during combustion are attracted to the sensor and produce a current. When there are enough ions, the device will work. When there are not enough of them, the column turns off.

  • the wick goes out after a few seconds after ignition;
  • during restart, the column operates longer;
  • You should turn on the device several times and it will function normally;
  • difficulties arise only after a long break.

Important! It is necessary to inspect the wiring running from the part to the board. For these purposes, contacts are checked

Next, the fixing screws are unscrewed and the heating electrode is placed in the hottest place of the fire.

This technique extends the service life of the indicator by years. When everything is normal with the contacts and connections, the element needs to be replaced.

Wear of the water unit membrane

The effective operation of the device will depend on the serviceability of each component and mechanism. The membrane in such a heater is one of the most important components, but wear occurs over time.

A flexible membrane will be located at the base of the assembly and respond to changes in system pressure. When the mixer opens, the rubber element will bend under pressure and push out the stem. It will turn on the gas valve, causing fuel to flow into the burner.

Important! With intensive use of the device, the membrane will wear out. The rubber will stretch, become clogged and damaged.

As a result, fuel will not flow into the burner: the device does not start or lights up, but immediately goes out.

  • Pressure force of gas and water. When the tap opens, you need to calculate how many liters will be consumed per minute. Within normal limits it will be 2-3 liters. The gas supply can be determined visually by looking at the fire.
  • Fire position. In devices with wick ignition, the flame burns from the edge and has a height of at least 30-50 mm. If not, then check the jets for clogging. Once the cleaning is complete, you need to look at the fire again. When the situation has not changed, the problem is in the diaphragm.

  • Ignition speakers should click when the button is pressed. This means the diaphragm is working. When there are no sounds, the part is probably broken.
  • In a number of models, a rod that controls the functioning of the control unit helps to identify a breakdown. The protective cover is removed and the water opens. When the rod is immobilized, the diaphragm needs to be replaced.

When a breakdown is found, you need to choose the right replacement part.

The wick is clogged with dust

In products with an igniter, such an element often becomes clogged. The fire will become weak and a yellowish tint will appear. However, a change in the color of the fire also indicates a lack of air in the gas-air mixture.

The result is that the column either does not ignite the burner at all, or will perform its functions when a large volume of fuel arrives. In the latter situation, a certain click is felt. To clean the element, you will need 2 screwdrivers and an adjustable wrench.

  • The case is removed - the adjustment handles are pulled out, the bolts in the corners from the bottom are unscrewed, the cover is lifted and removed.
  • The traction sensor tube and the one that draws in fuel are unscrewed.
  • The screws are removed and the structure is disassembled.
  • The nozzle is cleaned, the tee is blown out, and assembled.

Clogging occurs in the draft indicator, which is why the igniter begins to smoke. When dust and dirt are removed, the igniter lights up with a stable blue flame.

Important! When the column is cleaned, the device is somewhat noisy. The sound will be produced by air being sucked through the cracks in the wick guide housing

It is possible to get rid of the noise by tightening the wick screws a little.

Peculiarities

Electrolux water heaters are equipment that can heat water and maintain its temperature for a long time without interruption. The design can perform its functions in any conditions. The technical features of the devices provide the speakers with reliability and safety. The water heating equipment of this company is capable of working not only at one or several water intake points. It has found wide use both in the domestic sphere and in offices.

Each model has its own characteristics and performance, so when choosing a product, the buyer should be guided by personal taste and needs. Let's look at the main characteristics of Electrolux speakers.

  • Power. The manufacturing company sells a product that can be of three types and differ from each other in performance and power: low-power equipment - 17-19 kilowatts; medium power - 20-24 kilowatts; powerful - 25-31 kilowatts. Each presented option can work at a certain number of water intake points.
  • Control method. The manual control method has long been outdated; it has been replaced by a new, more improved one. Modern models of Electrolux geysers have a built-in burner with independent power modeling. Thanks to this, the equipment is able to control the temperature regime and maintain it at the required level, even with insufficient pressure. The automatic system independently selects and regulates the temperature.
  • Type of ignition. The manufacturer sells several models of geysers: with manual, automatic and piezo ignition. Equipment of the first option is now practically not found. Automatic ignition is the most convenient option to use.
  • Safety. Electrolux speakers are equipped with three-level and four-level security. When unexpected interruptions occur in the system, for example, pressure changes, a gas or water leak occurs, the device turns off automatically.

Electrolux water heating equipment is characterized not only by improved technical parameters, but also by an attractive design. Everyone will be able to choose the ideal option that will fit perfectly into the interior. Gas water heaters are presented both in a minimalist style and with an improved external panel. Devices on the front panel of which you can change pictures to suit the style of the room are very popular.

Specifics

Ariston geysers are characterized by their small size and conventional design. As a result, such equipment can easily fit into rooms of different sizes and different interiors. Plus, the equipment has design features that highlight it among substitutes from other brands. The design of the gas water heater is based on European technologies. Compliance with similar design methods makes it possible to provide all devices with a high safety parameter.

To ensure that the operation of water heating equipment is not dangerous, all models are equipped with several types of safety systems. Such systems significantly reduce the likelihood of dangerous situations occurring.

Typical protective systems built into all Ariston models include:

  • fuel control system;
  • device protection system against overheating;
  • system that monitors temperature regimes;
  • traction device system.

Another significant specificity of a water heating column is sound insulation. During the operating period, the device does not create excessive noise. When ignited, the appliance makes small vibrating sounds. In addition to the indicated positive properties, there is one that performs an extraordinary technique. The device allows the owner to select a suitable operating mode that suits a specific operating condition. The newly released equipment is configured to operate normally. Due to this, each client needs to configure the column according to the selected mode, in accordance with the rules of the operating instructions.

Troubleshooting procedure

Heating system

With a rapid drop in pressure, a leak can be easily detected by puddles and wet spots. But if it is insignificant (the Ariston 108 boiler error appears only a few days, or even weeks after replenishment), it is extremely difficult to identify it during the season. Droplets of moisture flowing through a microcrack from heated batteries and pipes quickly evaporate

Yellowness at the site of the defect will appear only when the water quality is low, but even such an influx cannot always be detected visually. If you suspect a circuit leak and error 108 appears, it is recommended to pay special attention to its problem areas:

  • connections of pipes, fittings, insertion points;
  • radiator plugs and seams;
  • elements of shut-off valves (taps, valves, plugs).
  • Leaks in pipe joints, fittings, tapping points
  • Leaks in plugs and seams of heating radiators
  • Leakage in areas of shut-off valves (taps, valves, plugs)

Why Electrolux

The Electrolux water heater is one of the best solutions available on the market today. The choice can be made based on your requirements and budget. The manufacturer has simple, but reliable, productive models. If you need to purchase a high-quality unit and save money, just choose a device with a minimum set of required functions.

All the advantages of brand gas water heaters:

  • Safety;
  • Cost-effective;
  • Attractive design;
  • Large selection of additional functions;
  • Availability of security and control systems;
  • Durability.

In the public domain you can find reviews of different models, look at prices, and compare the characteristics of certain modifications. There are also enough Electrolux services, so there are no problems with maintenance and repairs.

Range of models

The Ariston brand produces hundreds of models of water heaters. Good consumer reviews prove firsthand that this brand is considered number one in the market for the production of gas appliances. The Ariston Fast Evo model is a very popular one of the entire line of heaters. The model is available in two versions, differing in performance (11 and 14 liters per minute). This is a smokeless automatic machine with electric ignition. The device requires only two batteries to operate. Plus, the model has a built-in flame modulation system. Such a system makes it possible to maintain temperature constancy.

The main positive qualities of Ariston Fast Evo include:

  • ability to work at 2 water intake points;
  • ignition occurs at the lowest pressure levels;
  • comfortable outlet temperature.

Another common model is part of the Marco Polo series - Gi7S with a closed firebox. The device is equipped with a flow-type heater and does not have a smoke exhaust. The main feature of the device is that the pipe is led outside, therefore, gaseous, liquid and solid substances do not remain in the room, but go outside. Gi7S is the most powerful device, which makes it very energy efficient. Of the more inexpensive models, Ariston CA 11P is in great demand. The device is designed in a classic style and is easy to operate. It stably maintains the set parameters and does not upset the settings.

Plus, the boiler heats up in stages, without making any noise.

E3 or 3 red LED flashes - no flame when igniting.

The column starts, the main burner lights up and goes out after 5 seconds of gas burning. The automatic ignition clicks when the gas is burning.

Reason #1. The flame ionization electrode is faulty. The flame ionization electrode checks the current ionization. If no flame is detected within 7 seconds, the column will restart again.

Reason #2.
The electrode gap has increased or decreased. Adjust the ignition electrode gap. The wires are checked for the integrity of the insulator.

About company

Ariston is an Italian brand that has been supplying Europe with gas equipment for hundreds of years. The company's products are famous for their quality; they offer a wide variety of household appliances - from dishwashers to water heaters. The location of the headquarters is Fabriano. After rebranding in 2005, the company's name changed to Indesit Company. This concern, in addition to Ariston, owns the brands Hotpoint, Indesit and Scholtes. Today Ariston ranks third in the global ranking of sales of household appliances.

First steps

  • Ariston CARES X 24 FF boiler control panel. Click the Reset button.
  • Boiler control panel Ariston EGIS PLUS Reset
  • Boiler control panel Ariston bs 24 Reset button
  • Using the pressure gauge (display) of the boiler, check the pressure in the system and bring it to normal - 1.5 bar. If after some time it drops again and error 108 appears again, the conclusion is clear - a leak. It can occur in the heating system or in the Ariston boiler. Although we cannot exclude the possibility of incorrect operation (failure) of the air pressure switch sensor.
  • Ariston models of the GENUS series provide automatic replenishment of the heating circuit: activated by pressure


ARISTON (GENUS) BOILER AUTOMATIC FEE-UP VALVE