Neva instantaneous water heaters are simple and economical to operate and easy to maintain. Over time, the user may encounter equipment malfunctions that are not always easy to fix with their own hands. What to do if the Neva gas water heater does not light up? Do you want to know how to perform repairs without calling a technician? Then read our article.
How to understand why the Neva gas water heater does not light up?
There are situations when hot water is urgently needed, but as luck would have it, the water heater does not turn on. Usually, if you have an automatic water heater, you just need to open the tap and hot water will flow almost immediately. But when problems arise, no matter how much you open and close the tap, the area does not light up. It's a shame.
But in order to decide to invite a specialist, or to fix any “trifle” yourself, you need to understand the cause of the problem.
The column lights up on the second or third try
Sometimes you have to turn on the device several times so that it does not turn off on its own. The Neva gas water heater does not light up, what are the reasons?
Reason 1. Batteries. In automatic speakers, the reason lies in the batteries, the charge of which is only sufficient to ignite the fuse, but not for normal operation. When the batteries start to run low, the clicks are often “idle”.
Reason 2. Filters. They become clogged and water flows poorly.
Reason 3 . Weak traction. In this case, the column lights up a little later and with a bang. In such a situation, a ventilation valve will help out.
Reason 4: The spark plug or microswitch is misaligned. The latter is checked using an ohmmeter. If it turns out that the required values are not achieved, the part is replaced.
The spark plug is installed with a gap of five mm, having first loosened the screw. After this, the column starts on the first try.
The Neva gas water heater does not turn on: the igniter (wick) goes out
The fact is that the igniter, which should ignite the burner, ideally works continuously after switching on. It heats up the thermocouple that leads to the burner, and it lights up. But in case of certain malfunctions, the platform does not light up, and turning off the burner using sensors serves as protection. Otherwise there is a risk of gas poisoning.
To understand the reason for the attenuation, let’s look at how a thermocouple works. The thermocouple powers the solenoid valve, producing electromotive force. This happens when it is heated. When it begins to generate electromotive force, the rod enclosed in the valve begins to move and admit gas into the burner. But when the igniter goes out, the part stops heating, and the rod fires in the opposite direction: the valve closes and gas does not enter the burner.
Why does the pilot light not light up? Sometimes the insulation of the thermocouple conductor, consisting of an alloy of several metals, is broken, the conductor comes off, and the thermocouple does not work. Unfortunately, a soldering iron will not help here. The soldered part will not conduct current. You'll have to change the unit.
Attenuation of the wick also occurs due to a strong draft, or when gas does not flow. To make sure everything is fine with the part, test it using an AA battery. Connect the igniter to it. If it lights up, it means it’s working.
No spark
To understand why there is no spark, you should pay attention to the ignition. The problem may be a malfunction of the electric ignition or piezo ignition. To solve this problem, it is necessary to inspect the electrical parts to make sure that the ignition is working.
Note! In the event of a malfunction, the electrical parts should be replaced, since it was previously said that if there is a lack of necessary knowledge, it is not worthwhile to repair the electrical parts yourself.
List of the main reasons why the Neva dispenser does not work (different models) and their elimination
The geyser sometimes does not work for the most trivial reasons, and sometimes they are quite serious.
- Why does the Neva dispenser not light up: gas is not flowing . If the gas has not been shut off by the relevant services, then it is enough to turn on the water heater or turn on the water. and bring the match to the speaker window. The match lights up, which means gas is flowing in, and the reason that the column does not work lies elsewhere. Gas is cut off when repairs are being carried out or due to non-payment of bills. But, usually this is warned in advance. If gas does not flow, call the appropriate authorities, call specialists.
- Why the Neva gas water heater does not turn on: the ignition device does not work.
It is possible that the ignition element of the column - the igniter - has failed. In most cases, it is enough to disconnect the electrode from the ignition device. Then the spark will move to the center of the burner. It is also possible that the connections on the tube through which the gas passes are damaged.
- The gas water heater does not ignite: what are the reasons for the Neva gas heater when there is no draft?
Have you checked the chimney? It is possible that a blockage has formed in it. It will have to be cleaned of soot from the inside, and also to see if any leaves or other debris have gotten into it on the streets. To clean the outside, invite utility workers whose responsibilities include performing such work.
But insufficient traction also occurs if:
- There is another one next to the speaker vent.
- The ventilation pipe works for 2 devices.
- The pipe is built in such a way that it is too close to the chimney wall.
After finding out the cause and fixing the problem, the column will work normally.
- The Neva gas water heater does not ignite well: there is a short circuit in the automatic water heater circuit . In automatic speakers, a disturbance occurs in the electrical circuit between the switch and the power supply. For example, the column “Neva: 4510” does not light up for this reason quite often. In this case, a spark does not occur, and the reason is hidden in the terminals that connect them to the microswitch wires. It is also necessary to check whether there is oxidation in this place.
- The “Neva” column does not light up : there is no pressure. First of all, the water pressure knob on the column itself, which is located on the right, may be turned incorrectly. Usually it is set to the required level during installation of the column itself.
You should also check the filters:
- on the mixer;
- at the water node;
- on the cold water pipe.
But it happens that the water pressure is reduced by the authorities supplying it, then you will have to wait until it increases. The water pressure is also reduced due to clogging of the radiator itself, in which scale accumulates. We told you how to do this above. But it’s better not to take risks, but to contact the appropriate services that will quickly clean the radiator.
- The Neva gas water heater does not ignite well: overheating more than 90 degrees.
Such overheating occurs when all windows and doors are closed and almost no air enters the room. Column "Neva" 4511 or other models do not light up. The cause of the breakdown is the failure of the fuse. It should be checked and replaced if necessary. To check the part, you need to disconnect and short-circuit the leads. When you check it is working normally, simply replace the temperature sensor.
Prevention measures
For successful, safe and long-term operation of Neva speakers, you must adhere to the manufacturer’s instructions, as well as a number of simple rules, among which the most important point is the timely replacement of filters.
Note! In addition, the chamber should be cleaned and the igniters inspected from time to time.
Problems that can be prevented, namely problems with clogged heat exchanger tubes, as well as membrane wear, can be solved by installing additional water filters at the inlet.
If you identify any difficulties or questions in the operation and setup of geysers, it is advisable to immediately contact qualified technicians who will quickly and accurately diagnose the breakdown and set up the device.
The Neva Lux column does not light up. Error codes
L0 – lack of gas supply. The reasons lie in too high pressure in the gas line. There is a need to install a reduction gearbox. You may also need to adjust the temperature and water pressure.
E0 – no gas flowing.
E1 . The flame sensor does not send a signal to the control board. The reasons may be different, you need to check the gas supply, water supply, electrode blockage, contacts coming out, soot blockage.
E3 . The valve is activated before the signal from the flow sensor arrives. The intervention of a specialist is required, since either the valve itself or the electronic unit do not work.
E7 , the column does not light up, although there have already been seven attempts to turn it on. This happens when a gas or water block boils. Displacement of ionization sensors, failure of solenoid valves.
E8 , the traction sensor is activated. The reasons are either clogged ventilation or a breakdown of the sensor itself.
Problem with poor air flow
The problem is usually associated with a blockage in the exhaust of combustion products; soot may accumulate on them; there may also be a fault in the draft sensor. It is necessary to clean the combustion chamber and combustion product collector. The problem may also be your chimney.
Note! At home, it is possible to clean only the visible part of the chimney; specialists should clean the rest of the chimney. To check the air flow, you can use a lit match; to do this, you need to bring it to the window on the panel. When the flame deviates, we can conclude that there is an air flow.
Reviews and advice
When operating a speaker, sometimes people encounter other problems.
Victor installed alkaline batteries on the Neva 4510 column, but they “fly out” every 2-3 weeks, although the column only works for a year.
Viktor Matskalov installed the Neva 5514 column in place of the old one, which had been working for 12 years. When the batteries are replaced with new ones, it lights up, but then 3-4 clicks follow and the column goes out.
Oleg is very pleased with his semi-automatic speaker. There is only one problem: it is very difficult to change and install batteries.
https://cosmo-frost.ru/gazovye-kolonki-i-kotly/neispravnosti-gazovye-kolonki-i-kotly/gazovaya-kolonka-neva-ne-zazhigaetsya-ne-vklyuchaetsya-remont-etix-i-drugix- neispravnostej/
Advice: in order for the column to work longer and not break down, it is recommended to turn on cold water during its operation only as a last resort. Also, do not leave hot water in the radiator. It is better to drain it immediately, otherwise the radiator will quickly become clogged with scale.
https://boilervdom.ru/gaz-kolonki/obsluzhivanie/iz-gazovoj-kolonki-idet-kipyatok-chto-delat.html#:~:text=During%20%20work%20not%20recommended%2C,%20throughput %20faucet%20in%20shower
Useful video:
Electronics failures
The presence in modern models of a large presence of electronic components, on the one hand, ensures high safety of the device and ease of use, on the other hand, it complicates troubleshooting and subsequent repairs.
The causes of electronic malfunctions are mainly related to the influence of external factors - voltage drops in the network, lightning discharges entering the main gas pipes and water entering the circuit boards from leaks inside the device. In addition, failure of individual electronic components due to failures in the electronics itself cannot be ruled out.
The reason that the vector geyser does not light up may be a malfunction of the electronics, and the following situations may arise:
- No spark when igniting;
- Extinguished digital display;
- The device does not start the first time;
- During operation, an alarm signal is constantly displayed;
- Protection systems are constantly triggered;
- The device turns on and then turns off again;
- Diagnosis of a breakdown usually begins with checking the batteries; old or dead batteries need to be replaced with new ones. If there are traces of electrolyte leaking onto the terminals, it must be cleaned.
If this operation does not resolve the device problems, you must call a technician to check the electronic unit. Most often, in such models, the electronics unit cannot be repaired; it is simply replaced with a new one. When replacing a unit, the technician must inspect all components of the device, and when connecting a new unit, in addition, test the system and configure its parameters
Particular attention is paid to the presence of leaks at the junction points and the integrity of the heat exchanger
Error E8 - no traction
The column turns off after 2..5 minutes of operation. Restarting becomes possible only after cooling down - 2..3 minutes.
Reason #1. Lack of draft in the chimney. Clean the chimney.
Reason #2. Soot on the heat exchanger. Increased accumulation of soot on the heat exchanger, which prevents the passage of carbon monoxide into the chimney. To resolve the problem, the column must be serviced.
Reason #3. The traction sensor is faulty. The traction sensor works to break. Over time, the sensor becomes very sensitive to vibrations and may turn off the column during heating. Therefore, if this error occurs, the sensor will be checked for functionality.
Ways to prevent malfunctions
When purchasing a device, you should pay attention to the minimum water pressure required for the normal functioning of the device. The passport data must be compared with the water pressure in the apartment.
For the column to work properly, you must:
- carry out preventive maintenance once a year or more often;
- inspect the chimney a couple of times a year and clean it, if necessary;
- clean parts from scale and soot;
- provide adequate ventilation.