At what depth to bury a sewer pipe in a private house - all options

Before you start installing sewer pipes in a private building, for example, in a cottage, you must first develop layout drawings and draw a laying diagram.
Such materials will help to correctly install plumbing products, calculate the correct slope of pipes and make an estimate of the materials needed for the work.

The system created according to the drawings will work without breakdowns, and if a blockage occurs, it can be quickly eliminated.

The article was written specifically for those involved in the construction and installation of sewerage systems. Builders will be able, based on the text below, to draw up a sewer laying diagram for an individual house. Examples of calculations of external and internal sewer pipe installation systems are given.

Craftsmen will be able to calculate to what depth to bury the sewer pipe. It will be possible to calculate the necessary consumables for the installation of an autonomous sewer system, laid independently both indoors and around the house.

Internal circuit

The development of the scheme should begin with the most distant plumbing fixture installed on the top floor. The horizontal lines drawn must necessarily come to the riser. To save materials for work, plumbing fixtures are placed on different floors, but maintaining the same vertical.

The home sewer system includes:

  • A water seal that protects the room from unpleasant odors;
  • Pipes through which wastewater enters the external system;
  • Knees;
  • Tees;
  • Clamps that support pipes and create a certain slope;
  • Central riser

When installing a sewer system, it is very important to monitor the transition of pipes. It should not move from a larger diameter to a smaller one. To take this nuance into account, you need to install the toilet on the layout at the closest distance from the riser.

The drawing of the internal system includes several very important parameters:

  • Number of floors;
  • Basement;
  • Number of plumbing fixtures;
  • Number of apartments.

The diagram must be drawn to a certain scale. This will help you quickly understand the pipe layout when you need to identify problems in the event of an emergency.

External line

To install a sewer system for an individual house, it is necessary to draw a diagram taking into account the surrounding landscape. Professionals recommend placing the septic tank as low as possible, and the pipes should have a slight slope.

To determine which treatment system needs to be taken as a basis and at what depth the pipes will lie, you need to pay attention to the following factors:

  • Groundwater;
  • Type of soil;
  • Freezing depth.

The construction of external sewerage usually begins with laying a pipeline from the foundation. Drains should be discharged towards the constructed cesspool. Any turn of the pipe must be equipped with a special revision, in the form of an adapter equipped with a lid. Through it you can easily remove the blockage.

An inspection well is mounted on the outside and a ventilation hood is installed.

The ventilation pipes exit through a riser with an installed drain pipe. Since it will always have a very strong unpleasant odor, such a pipe should be installed as far as possible from the windows or next to the smoker.

It is prohibited to combine the fan pipe with an ordinary ventilation shaft. The umbrella can be replaced with a special vacuum valve installed at the top of the riser. Remember that it has nothing to do with the check valve.

Pipeline insulation


An example of external network insulation

Insulating a sewer pipe helps prevent the formation of condensation and ice on the inner walls of the channel. There are many options for installing a heat insulator, but the most effective and reliable is the use of molded insulation (shell). Other types of thermal insulation materials can be used:

  • foamed polyethylene;
  • liquid polyurethane foam;
  • polystyrene foam or polystyrene foam.

The main requirement for the material is complete impermeability and physical resistance to moisture. It would be a mistake to use mineral wool, loose or loose types of insulation, since they will not be able to form an airtight seal for the water that has filled the trench or tray.

It must be remembered that the greater the depth of the sewer pipes, the closer the groundwater will be located. During a seasonal increase in their level, the pipe may be immersed in water, and if frost suddenly strikes, the system will inevitably freeze. Therefore, in parallel with the installation of a heat insulator, attention should also be paid to the waterproofing of the system.

You may also like: Heating cable for sewer pipes: types, advantages, installation

Types of tanks, their positive and negative sides

The final part of the system is the tank where cleaning is carried out. If there is no central collector through which the drains are collected, then autonomous installations are used.

cesspool

This is perhaps the cheapest option. It is easy to dig a hole in the right place. However, it cannot always cope with large volumes of wastewater. Dirt can become a source of unpleasant odors in groundwater.

Septic tank

This structure can be made of brick and filled with concrete. You can also install standard reinforced concrete rings. If the septic tank is well made, it can be used for many years, as it is highly durable. The disadvantage of this design is long installation and large financial investments.

Self-contained installation, industrial type

Of course, such a design always costs much more, but all costs are fully covered thanks to the fast construction and very high quality. Such installations will work for a very long time with virtually no breakdowns.

Biological treatment system

We can safely say about such a system “the most expensive”. For its operation it is necessary to supply constant electrical power. However, it has high productivity and high-quality cleaning.

How to choose a location for a wastewater receiver, how to calculate its parameters

Whatever the type of receiver, its volume must correspond to the three daily norms consumed by all residents of the house.

According to established standards, one person consumes 200 liters per day. Therefore, the volume of the receiver should be 600 liters. If the treatment plant has several connected tanks, the total volume will be equal to their sum.

The choice of receiver location depends on several requirements.

The standards also establish distances to particularly important objects; they must comply with accepted standards:

  • 50 meters – to the drinking water pipe;
  • 5 meters – to the road;
  • 30 meters – to the reservoir;
  • 5 meters - to the living space.

At what depth should sewer pipes be laid?

Technological standards (SNiP) establish a certain depth of sewerage in a private house.


To more accurately determine this value, you need to familiarize yourself with the zone map.

It shows the depth of soil freezing in various areas of our country. For example, in Moscow, the depth of laying a sewer pipe should be at least 1.4 m. For Sochi, this value is much less - 0.8 meters.

These parameters are taken taking into account the terrain when the soil freezes. If pipes are installed with a cross-section of less than 500 mm than indicated on the map, it is necessary to subtract 0.3 meters from this value. When it is necessary to lay large-diameter sewer pipes, the laying depth should be reduced by 0.5 meters.

Useful tips

The depth of sewer installation is an important, but not the only question that needs to be answered for proper installation of a septic tank. The treatment facility must be equipped in accordance with SNiP and meet certain requirements. Among them:

  • the septic tank should not be located in a low-lying area, next to a well or pond;
  • You should not install a disposal facility in places where the groundwater depth is less than 150 cm - they can fill with VOCs;
  • if the soil freezes more than 140 cm, there is no way to do without insulating the sewer system;
  • It is better to install a septic tank in soil where there is a minimum of clay.

It should be noted that in the case where the depth of the sewerage system and the placement of the septic tank is lower than the groundwater flow, the disposal unit must be sealed. This is a very important point that cannot be neglected. Otherwise, a situation may arise in which it becomes impossible to use the septic tank, and everything will have to be redone.

There is another non-obvious nuance - tall trees should not be planted next to the waste disposal unit. Their root system goes deep into the ground and has a large branching. Over time, plant roots can damage the septic tank, compromising its integrity.

At what depth is the sewer pipe laid near the house?

Standardized standards indicate that the pipe leaving the room must be positioned so that it rises above the average freezing depth by approximately 30 cm.

The depth of the trenches should exceed 70 cm. For the middle zone, the minimum depth of the sewerage should reach 50 cm. This is quite enough if there is no area nearby that needs to be cleared of snow and there is no roadway.


It is very important to comply with the last requirements described above. The fact is that the pressure of the machines can lead to pipeline breakdown, and if there is a large accumulation of snow, the pipe will simply freeze.

To create gravity flow of sewage drains, you need to know exactly what slope needs to be created for the sewer pipe, especially in a private building.

In principle, you can ask your neighbors. They know well what trench depth is needed. They have already laid such pipes and tested the system. Therefore, their data will be the most optimal, especially for winter.

If you have any doubts or difficulties when carrying out such plumbing work, you should contact a professional. Such companies employ highly qualified specialists with extensive experience and appropriate tools. If you do not have the skills for such work, then independent operations can lead to damage to the material and additional financial costs.

Bookmark depth and optimal tilt amount

For pipes with a diameter of up to 50 mm, SNiP recommends making the slope equal to 3 cm per one meter of installation.

If the pipe cross-section reaches 100 mm, then the slope can be reduced by one centimeter. To prevent the sewer system from becoming clogged and possible “greasing” to occur, it is advisable to increase the slope by about half a centimeter for each meter of wiring.

The same angle of inclination is maintained when laying pipes in the area near the house. A sleeve is installed in the foundation. Its diameter is 15 cm larger than the main pipe. Thanks to the sleeve, a transition to the external sewer occurs. It is mounted above the freezing level of the soil by 30 cm.

Then a trench is dug to provide access to the septic tank. Its approximate depth should be no more than one meter.


Do not bury sewer pipes below the existing freezing level. Its average value does not exceed 1.6 m. Such work will be very unprofitable, since it will be necessary to make the septic tank deeper. If a constant slope of approximately 4–5 m is maintained, groundwater may appear.

Such work requires additional financial investments, since it is necessary to install additional concrete rings and special high-strength corrugated pipes. They withstand the pressure of the drain perfectly, they do not deform with a large mass of soil.

The normal temperature of the drain is always higher than in the room, so the pipes do not freeze. Sometimes they are insulated with thermal insulation or a heating cable is laid.

The principle of operation of a septic tank

To make an autonomous sewer system in a country house, you can purchase a factory-made septic tank and install it yourself. It is made of fiberglass, polyethylene, and metal containers are also available. Such tanks are completely sealed and have a neck and hatch. A septic tank is the optimal solution when the groundwater level in the area where the cottage is located is quite high.

Wastewater consists of organic matter, which goes through a mineralization process during waste settling. This happens in two stages: first, wastewater flows through sewer pipes into a reservoir, where it is clarified. After initial treatment, wastewater is absorbed into the soil or sent for further treatment to special filtration facilities.

The septic tank is made in the form of a round or rectangular well. It consists of 1–3 tanks separated from each other, the bottom and walls of which do not allow water to pass through. Above the septic tank there are floor slabs with openings for hatches, through which you can inspect and repair equipment. From the outside, the surface is protected with waterproofing material - roll or coating type. The grooves of the pit are covered with 50 cm of soil, and there is also a slope to prevent natural precipitation from accumulating.

The functioning of a septic tank is as follows: sewage slowly passes through the tanks. As a result, organic particles settle down and the water becomes clarified. Then, over time, the sediment disintegrates under the influence of anaerobic bacteria.

Solid organic matter partially transforms into a gaseous state and evaporates. The remaining part is mineralized.

Method for calculating the depth of a pipe connected to a storage tank

The size of the pipe outlet in the room increases by the length of the external line, multiplied by a coefficient, the value of which is selected according to the diameter of the pipe:

  • D 50 mm – 0.03;
  • D 110 mm – 0.02;
  • D 160 mm – 0.008;
  • D 200 mm – 0.007;

The calculation is carried out according to the formula:

h2=h1+l*k+g,

h2 – depth of the point from where the exit and connection to the storage tank is made;

h1 – the value of the exit from the room. Take 1.4 m;

l – distance from the foundation to the storage well. Usually 10 meters.

k is the slope coefficient of the sewer pipe, always equal to 0.02;

g – natural slope of the surface. Usually does not exceed 0.3 m.

h2=1.4+10*0.02+0.3=1.9 m.

According to the calculation data, a sewer trench is created.

6.Design and calculation of rainwater drainage

The rainwater network receives rain and melt water. Typically, a rain network is designed to carry the maximum intensity of rain for a given area. The rain network consists of internal watercourses and a rain street network.

Internal watercourses collect rainwater from roofs, which then flows into the street network. Rainwater generated on the free surface of the earth enters the network through storm water inlets.

1. Determination of calculated rain parameters.

The canalized facility is located in the city of Glubokoe

. Let's define parameter A:

,

Where:

q20 – rain intensity for 20 minutes with a period of one-time network overflow equal to 1 year l/s ha. Determined from the table. A1 (q20=102); mr – the amount of rain per year, determined from the table. A3; mr = 164 Р – period of one-time overflow of the calculated rain intensity, year (P=1). Determined from the table. B1 depending on the value of q20 and the nature of the location of the collectors. n—climatic parameter (n=0.67). Determined according to Table A2. 2. The value of q20р is determined by the formula: We assumed that there is an intra-block network and tcon = 5, then: 3. We determine the average runoff coefficient for the canalized area. The value of the runoff coefficient Zmid for various coatings is determined depending on the value of parameter A according to table. AT 2 . It is more convenient to determine the average runoff coefficient in tabular form:

Type of coverage Drain area, % Ztable Z calc
Roof 22 0,265 0,0583
Asphalt 25 0,265 0,0662
Cobblestone pavements 17 0,224 0,0381
Crushed stone coverings 21 0,125 0,0263
Lawns 15 0,038 0,0057

Zmid=0.194

4. Determine the runoff module q0, l/s ha:

q= β Zmid q20p ,

Where:

β is a coefficient that takes into account the filling of the free capacity of the network during the period when the pressure regime occurs (β = 0.65). Determined from the table. 6.2 depending on the indicator n. Then:

q0= β· Zmid·q20p=0.65·0.194·73.07=9.2 l/s ha.

At each section, the numerical flow rate is determined using the formula: Qnumber=q·F

Next, a hydraulic calculation of the rain collector is performed, which is summarized in table 6.1 “Hydraulic calculation of the rain collector.”

What problems may arise when installing a sewage disposal system, and how to solve them

In some cases, the depth of sewer installation during installation in a cottage depends on some external factors.


It happens that installation is simply impossible, or it requires huge financial costs. One of the reasons is considered to be rock located between the house and the well. In such a situation, it is impossible to make a standard trench, since the soil has a very complex structure.

The only way out of this situation is to insulate the pipes. Before you start installing the structure, you must wrap the pipeline with several thick layers of insulation, and then lay it to a depth of no more than 30 cm. It will be possible to create heating for the pipe, for which you will need to lay a heating cable under the pipe.