Where to install an air conditioner in an apartment, house, room: 7 important tips


Most residents of our vast Motherland, one way or another, face the problem of summer heat! Each of us understands that the best salvation from the heat in the apartment is a split system. The process of purchasing it is accompanied by two main questions: where to install the air conditioner in the apartment and which model to choose? Today I will tell you about the most successful options for the location of the air conditioner.

When we are just planning to purchase a “split”, many have no idea where in the apartment it should be located. For the first time, we think about where it is even possible to place the device so that it works correctly and efficiently. Many people have two versions in their heads:

  • the first is the installation of one large air conditioner for the entire apartment (usually somewhere in the corridor);
  • the second version is the installation of one or more split systems in certain rooms.

I stick to the second option, when the “split” is calculated for one room. And it’s even better when its power takes into account a small margin. Then the neighboring rooms can be partially cooled.

No. 1. Types of air conditioners

Air conditioners are different, and therefore the rules for their placement are different. Without going into details and features of choice, we will note only the main types of cooling devices that can be used in a home:

Standard equipment

The standard configuration of a split system usually includes such components.

  1. Outdoor unit. Sometimes it can be equipped with brackets for mounting an external module.

  2. Indoor unit (hair dryer).

  3. Metal, perforated frame (can have different shapes). Used for mounting the indoor unit.

  4. Nuts that are used if you need to lengthen the tubes - 4 pcs., as well as self-tapping screws with plastic dowels for mounting the frame.

  5. Drainage (tube through which moisture is removed from the internal module of the unit). If you need to extend the drainage pipe, you can use a regular metal-plastic pipe (water pipe).

  6. Remote control.

  7. User manual.

Important! To install the air conditioner yourself and put it into operation, you need to supplement the standard equipment of the device.

No. 2. Basic rules for installing an air conditioner in an apartment

Anyone who is going to equip their home with an air conditioner is primarily concerned with the issues of choosing a device that is suitable for its technical characteristics. The widest range of climate control equipment is presented on the websites of online stores, and the employees of the selected company will help you choose the most suitable model, carry out high-quality installation of the air conditioner and will be able to provide further maintenance of the equipment (cleaning, repairs, etc.). Of course, you will have to decide on the location of the air conditioner in the apartment

To ensure that the operation of the air conditioner is completely safe for health, follow these rules :

The smaller the room, the more difficult it is to find a suitable place to install the air conditioner, but in this case mobile devices can save the day.

Vacuum gauge readings

There are several possible options for the behavior of the vacuum gauge needle after the device is turned off:

  1. The readings indicate an increase in pressure, while the arrow again drops to the value of 1 atm, which was before the start of the evacuation process.
  2. The readings again indicate an increase in pressure, but the needle, falling, does not reach the 1 atm mark.
  3. The arrow does not change its position for more than fifteen minutes, showing the value “0”.

What could this mean? In the first option, when the arrow has reached a value of 1 atm at elevated pressure, you need to understand that there is most likely a leak in the system and it needs to be eliminated as quickly as possible. In the second option, where the arrow does not reach the value of 1 atm. at the same increased pressure means that it is necessary to continue the evacuation process, since there is still moisture in the system. The last option indicates a positive result of the operation, i.e. that the evacuation went well and moisture and air were completely removed from the system.

There are cases when the lack of tightness is detected much later, when operating pressure has already been created in the system. Therefore, after checking for vacuum, it is best to additionally test for tightness under pressure.

No. 3. Where to install the air conditioner in the bedroom?

The optimal place for an air conditioner in the bedroom is the wall at the head of the bed, but the device is not hung directly above the bed, but on the side of the bed. In this case, cold air will concentrate closer to the feet of vacationers, and not near the head.

An acceptable option is to position the air conditioner so that the cool air flows perpendicular to the sleeping area and passes at the foot of the bed.

You can also hang the air conditioner above the door. In this case, the block will not be noticeable when entering the room, and if you leave the door open, the coolness will spread outside the bedroom. The only disadvantage of this option is the long freon route.

The worst options for placing an air conditioner in the bedroom include installing it opposite the bed, when cold air hits the heads of vacationers, and opposite the front door, when the unit immediately catches your eye upon entering the room.

The place near the window is also suitable for placing an air conditioner, but here you need to be extremely careful in terms of choosing curtains. Massive structures will reduce the efficiency of the device if they disrupt normal air circulation.

If you still can’t find the ideal place, you can pay attention to an air conditioner with multi-directional air flow . If something happens, the lower flap can be closed by directing cool air in some direction. In any case, it is better not to leave the air conditioner on overnight.

Crimping

After compressing the refrigerant in the compressor, and then in the pipeline section before the condenser, in the condenser itself and in the pipeline after the condenser (before the throttling valve), the refrigerant is under high pressure - 20-30, and sometimes 40 bar. All connections in the refrigeration circuit must be guaranteed to withstand this pressure. Therefore, after collecting the entire refrigeration circuit, the system is tested for leaks, i.e. pressure testing is performed. This occurs after complete installation of the refrigeration circuit of all indoor units, but before thermal insulation of the pipelines, before evacuation of the system. This is done in order to check the tightness of the refrigeration circuit and, if a leak is detected, quickly find it. To do this, the system is filled with nitrogen gas through the service connection.

Nitrogen is used at 99% purity to prevent various contaminants from entering the pipelines. Nitrogen is contained in cylinders at a pressure of about 155 bar or slightly more. Direct connection of the cylinder to the system is excluded. It is necessary to use a reducer, which allows you to reduce the pressure and fill with nitrogen at a lower pressure - 35-42 bar. The gearbox must be equipped with a safety valve with a response pressure of 70-75 bar. Refilling is always done through conventional hoses that are used for refrigerant charging.

After this, the drop in pressure is observed throughout the day. If the pressure drops, it means that there is a leak in the refrigeration circuit, which most often occurs in solder joints, in threaded connections. In such places it can be checked in several ways:

  • by ear (possibly hissing);
  • soaping (see the appearance of bubbles);
  • using a leak detector.

Once a leak is detected, it is repaired and the pressure testing process is repeated. Pressure testing is repeated until the pressure in the circuit drops throughout the day.

In some cases, specialists do not use nitrogen for pressure testing, but immediately use a refrigerant. All refrigerants in the refrigeration circuit can be in a different state of aggregation, and when charged in gaseous form, entering, for example, a condenser, they can slowly condense, which entails a gradual drop in pressure in the system. This drop in pressure can be confused with a refrigerant leak from the system.

Another reason why you should not check the tightness with a refrigerant is its cost (it is much more expensive than nitrogen)

No. 4. Air conditioning in living room and kitchen

When choosing a place for an air conditioner in the living room , you should be guided by the rules described above, but this, alas, is not always enough. In a room where household members and guests gather, it is more important than anywhere else that the block is as inconspicuous as possible and literally disappears into the interior. Directing air onto sofas, armchairs and the dining table is strictly not recommended.

In the kitchen, which is usually a very small space, it is difficult to fit an air conditioner, especially considering the numerous hazards in the form of the stove, refrigerator, radiators and speakers. If you absolutely cannot do without an air conditioner, then pay attention to the most compact and corner models.

When is vacuuming necessary?

During installation, both units are connected to each other by copper pipes for refrigerant circulation. This is the air conditioner circuit. After laying the copper line, all pipes are hermetically connected and tightened to prevent atmospheric air from entering inside. Even with great efforts to remove air from the pipes by blowing, it will not be possible to completely get rid of it.

Evacuation of an air conditioner is a mandatory procedure both for household devices, where the length of the line does not exceed 2 meters, and for office or industrial installations, where the length of freon pipes can reach tens of meters.

What is it for:

  • air vapor dissolves in the oil, which is responsible for lubricating the compressor parts, this leads to a change in the characteristics of the lubricant and it performs its functions worse: it does not form a dense film on the surface of the rubbing parts; the mechanism wears out faster and the risk of compressor jamming increases;
  • moisture changes the chemical characteristics of the coolant, which threatens to reduce the performance of the air conditioner; signs of freezing will be noticeable on the circuit.

No. 5. Air conditioning in the children's room

It is better not to install air conditioning in a children's room at all, since children are especially sensitive to the flow of cool air and can quickly get sick. If it’s really hot and you can’t breathe in the nursery at all, then a mobile air conditioner . It can be turned on for a short time and directs the air flow to the safest place. In principle, if you turn on the air conditioner only when there are no children in the room, and use it to maintain the optimal temperature in the room, then you can install a split system, guided by the rules written above.

What do you need to prepare for DIY installation?

In order for climate control equipment to work correctly, it is necessary to follow the rules for installing the air conditioner. The work of professional installers is expensive, but here you can be sure that the devices will function properly and serve you for a long time.

If you are far from technology, then it is better not to take risks and let the professionals do their job. When a home handyman has already disassembled and assembled electrical appliances, then installing a split system independently is a feasible task for him.

However, for this you will need to prepare, prepare the necessary equipment:

  • flarer
  • Pipe cutter
  • Trimmer
  • Drill
  • Hammer

To perform installation work with maximum quality on routes of 6 m and above, you will need a vacuum pump.

No. 6. How to properly fit an air conditioner into the interior?

Choosing the most suitable location for the air conditioner, as it turns out, is only half the battle. It is also important that the block does not stand out too much, but better yet, fits organically into the interior. It is impossible to hide the device behind a decorative panel or screen for the reasons described above, but there are several ways to fit the air conditioner into the space of the room as organically as possible:

Gating stage

Marking the grooves for the air conditioner is done in several ways. It depends on the drainage system:

  1. If all the pipes - freon and drainage - run side by side, the recess is made at an angle of 3 degrees so that condensate does not stagnate.
  2. If the drainage is located separately, the slope of the groove is needed only for the drainage hose. The freon line is laid without a slope. Can be done on the ceiling or walls.
  3. If it is not possible to drain the drainage liquid by gravity, it is necessary to install a pump with which water will be removed from the system.

When marking the recess, you cannot make sharp turns, since it will be impossible to bend the pipes for such a turn. Sharp corners must be avoided, otherwise the copper tube will crease and freon will not circulate freely.

The recess is made 60 mm wide and 40 mm high. For a drainage tube 20mm deep and wide. The work is carried out with a wall chaser. An ordinary grinder and chisel are not suitable, as they can destroy the wall. In a panel house, this can disrupt the load-bearing performance of the walls.

The original models have eyeliner on the left side. In Chinese air conditioners, sometimes there are pipe inlets on the right.

TOP best models

There are many models of vacuum pumps on the market today. Devices such as Value VE115N, Value V-i220SV, Value VE-2100 are very popular among buyers in different price segments. They have collected many positive reviews and recommendations, which is a kind of guarantee of quality.

Best budget model

The Value VE115N pump is recognized as the leader in this category. This is a single-stage budget vacuum cleaner from a popular company with an extended service life. It provides high productivity - 51 l/min, has compact dimensions and weighs just under 7 kg. The power of the device is 185 W, the residual pressure in the system is 150 microns. The equipment has received greater accuracy in relation to previous models in the line. A wide inspection window is provided to check the oil level. The price of the device is within 5000 rubles.

The best model in the mid-price segment

In the category of semi-professional equipment in the mid-price segment, the Value V-i220SV model wins. The VI Series provides the deepest vacuum available from Value. This pump has a capacity of 51 l/min, a residual pressure of 1.6 Pa and a power of 250 W. It is equipped with its own vacuum gauge that helps monitor the residual pressure in the line. The design of the device includes an electromagnetic valve that automatically shuts off the input of the product after a power outage. Price – from 12900 rubles.

Best premium model

According to this criterion, many experts recognize the Value VE-2100 vacuum cleaner as the best. This is the most powerful 2-stage pump of this brand in the VE series. The vacuum depth is 2 Pa, productivity is 288 l/min, power is 750 W. The device operates from the network. Type – vane-rotor. The device is used for vacuuming climate control and refrigeration equipment. The price starts from 23,600 rubles.

Sources

  • https://masterfibre03.ru/otoplenie-montazh/vakuumirovanie-sistemy-kondicionirovaniya.html
  • https://MasterXoloda.ru/5/vakuumirovanie-i-proverka-kondicionera
  • https://oventilyatsii.ru/vakuumirovanie-kondicionera-svoimi-rukami.html
  • https://foundmaster.ru/climatic/chto-nuzhno-znat-o-vakuumirovanii-konditsionera.html
  • https://vozduhstroy.ru/kondicionery/vakuumirovanie.html
  • https://sovet-ingenera.com/vent/cond/vakuumirovanie-konditsionera.html
  • https://delta-instrument.ru/montazh/vakuumirovanie-kondicionera.html
  • https://venteler.ru/vakuumirovaniye-split-sistemy-poshagovaya-instruktsiya-po-primeneniyu/
  • https://konder77.ru/articles/obsluzhivanie-konditsionerov/vakuumirovanie-konditsionera/
  • https://odstroy.ru/vakuumirovanie-trassy-kondicionera-svoimi-rukami/

[collapse]

Service works

Soldering/rolling

Re-rolling (elimination of freon leakage) for a pair of copper ends (liquid/gas) pcs. 3,500 Soldering of copper tubes - 2 ends (liquid/gas)up to 3.0 kW (05/07/09 and 12 BTU) 1/4 and 3/8 pipe (6mm/9mm)Piece 2 500 Soldering copper tubes - 2 ends (liquid/gas) up to 6.0 kW (12/18 BTU) 1/4 and 1/2 pipe (6mm/12mm)Piece 2 500 Soldering copper tubes - 2 ends (liquid/gas) up to 11.0 kW (24/36 BTU) 3/8 and 5/8 pipe (9mm/15mm)Piece 3 300

Maintenance

Comprehensive air conditioner service up to 6.0 kW (18 BTU)Piece 3 500Comprehensive air conditioner service up to 11.0 kW (36 BTU)Piece 4 500

Refilling with freon

Full charge of refrigerant (freon R410A) pcs. 4,000 Full charge of refrigerant (freon R22A) pcs. 4,000 Full charge of refrigerant (freon R32A) pcs. 4,000 refill with refrigerant up to 200 gr. (freon R410A) Pcs. 2,000 Refilling with refrigerant up to 200 gr. (freon R22A) Pcs. 2,000 Refilling with refrigerant up to 200 gr. (freon R32A) Pieces 2,000

Other works

Complete diagnostics of the air conditioner (with an on-site technician) Units 3,700 Complete diagnostics of the air conditioner (without an on-site visit) Units 2,500 Minor repairs Units 1,500 False crew visit Units 1,000